VP150 Off Grid Solar Inverter 1/2KVA
HIGH FREQUENCY INVERTER DC 12/24V | MPPT 45A | PV 105V
It is a cost effective, intelligent solar inverter which accepts Solar & Utility input at the same time. The comprehensive LCD display offers user-configurable and easy-accessible button adjustment such as battery charging current, AC/solar charger priority and DC priority.When battery voltage is low,it will automatically switch to AC grid to supply continuous power to the loads.
Description
Product Description
■ Built-in 45A MPPT Solar Charge Controller
■ 15A@24V, 20A@12V standard charging current from utility AC
■ AC/solar priority for charging via MFD
■ Different charging mode for different kinds of batteries
■ Overload & short-circuit protection, Battery reverse polarity protection, Deep discharge protection
■ Auto restart while AC/solar is recovering Adjustable solar and utility charging current
■ Support two kinds of batteries include LiFePO4 Lithium Battery Pack and Lead-acid Battery.
■ Support one key battery type fast setting
■ Automatic activate protected lithium battery pack by Utility AC.
■ Automatic activate protected lithium battery pack by Solar PV
■ Low shutdown loss for energy storage system application
MODEL | VP150-1012 | VP150-2024 | ||
Nominal Battery System Voltage | 12VDC | 24VDC | ||
NVERTER OUTPUT | ||||
Rated Power | 1000VA / 600W | 2000VA / 1200W | ||
Waveform | Pure Sine Wave | |||
Nominal Output Voltage RMS | 230V | |||
Output Voltage Regulation | +10/-18% | |||
Output Frequency | 50Hz / 60Hz ± 1Hz | |||
Inverter Efficiency (Peak) | >90% | |||
Line Mode Efficiency | >95% | |||
Typical Transfer Time | Typical < 10ms , 20ms max | |||
AC INPUT | ||||
Voltage | 230VAC | |||
Voltage Range | 176~278VAC ± 3% | |||
Frequency Range | 45~65Hz ± 2Hz | |||
BATTERY | ||||
Note: Below Parameters (PB) Lead-acid Battery / (LI) LiFePO4 Lithium Battery Pack – 12V(4 Series) 24V(8 Series) | ||||
Nominal Input Voltage | 12VDC | 24VDC | ||
Low Battery Cutoff | 10.5VDC(PB) | 11.5VDC(LI) | 21.0VDC(PB) | 23.0VDC(LI) |
Low Battery Alarm | 11.0VDC(PB) | 12.0VDC(LI) | 22.0VDC(PB) | 24.0VDC(LI) |
Low Battery Voltage Recover | 12.5VDC(PB) | 12.8VDC(LI) | 25.0VDC(PB) | 25.6VDC(LI) |
High Battery Voltage Recover | 14.5VDC(PB) | 14.5VDC(LI) | 29.0VDC(PB) | 29.0VDC(LI) |
High Battery Voltage Cutoff | 15.0VDC(PB) | 15.0VDC(LI) | 30.0VDC(PB) | 30.0VDC(LI) |
SOLAR CHARGER & AC CHARGER | ||||
Charger Voltage boost | 14.4VDC(PB) | 14.4VDC(LI) | 28.8VDC(PB) | 28.8VDC(LI) |
Charger Voltage float | 13.8VDC(PB) | 14.4VDC(LI) | 27.6VDC(PB) | 28.8VDC(LI) |
Maximum PV Charge Current | 45A (max) | |||
Maximum PV Array Power | 700W | 1400W | ||
MPPT Operating Voltage Range | 14 ~ 75VDC | 28 ~ 75VDC | ||
Maximum PV Array Open Voltage | 105V | |||
Maximum Efficiency | > 95% | |||
Standby Power Consumption | < 2W | |||
AC Charging Current | 10A/20A (Can be set) | 7A/15A (Can be set) | ||
Maximum Charge Current AC+PV | 10~65A (Can be set) | 10~60A (Can be set) | ||
BYPASS & PROTECTION | ||||
Overload Protection (SMPS Load) | FUSE | |||
Output Short Circuit Protection | FUSE | |||
Bypass Fuse Rating | 7A | 10A | ||
Max Bypass Current | 7A | 10A | ||
PV Charge Fuse Current | 50A | |||
MECHANICAL SPECIFICATIONS | ||||
Machine Dimension (W*H*D) | 235*290*92mm | |||
Package Dimension (W*H*D) | 595*375*315mm | |||
N.W (kg) | 2.8kg | 3.0kg | ||
G.W (kg) | 3.5kg | 3.7kg | ||
OTHER | ||||
Operation Temperature Range | 0℃ to 40℃ | |||
Audible Noise | 50dB MAX | |||
Display | LED+LCD |