VP360 Off Grid Solar Inverter 8-12KW
Low Frequency Inverter DC 48V | PV 250V | MPPT 100/200A
VP3600 series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.
Description
Product Description
■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
■ Built-in MPPT solar charge controller 100A/200A
■ MPPT efficiency max 98%
■ Powerful charge rate up to 140Amp
■ Inside BMS function
■ DC start &Automatic Self-Diagnostic Function
■ WIFI / USB monitoring function (wi-fi optional)
■ Supporting AGS, BTS port
■ Compatible to generator
MODEL | VP360-8048 | VP360-10048 | VP360-12048 |
Nominal Battery System Voltage | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT | |||
Rated power | 8.0KW | 10.0KW | 12.0KW |
Surge rating | 24000VA | 30000VA | 36000VA |
Capable of starting electric motor | 4HP | 5HP | 6HP |
Waveform | Pure sine wave / same as input (bypass mode) | ||
Nominal output voltage RMS | 220V / 230V / 240VAC (±10%RMS) | ||
Output frequency | 50Hz / 60Hz ± 0.3Hz | ||
Inverter effciency(peak) | >88% | ||
Line mode efficiency | >95% | ||
Power factor | 1.0 | ||
Typical transfer time | 20ms(max) | ||
AC INPUT | |||
Voltage | 230VAC | ||
Selectable voltage range | 90-280 VAC (APL) | ||
Frequency range | 50Hz / 60Hz | ||
BATTERY | |||
Low battery voltage cutoff | 40-48VDC for 48VDC mode | ||
Low battery voltage recover | 42-50VDC for 48VDC mode | ||
High battery voltage cutoff | 60VDC for 48VDC mode | ||
High battery voltage recover | 57VDC for 48VDC mode | ||
Idle consumption-search mode | <80W when power saver on | ||
AC CHARGER | |||
Output voltage | Depends on battery type | ||
Charger AC input breaker rating | 80A | 100A | 100A |
Overcharge protection S.D. | 62.8VDC for 48VDC mode | ||
Maximum charge current | 100A | 120A | 140A |
BTS | |||
Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||
BYPASS & PROTECTION | |||
Input voltage waveform | Sine wave (grid or generator) | ||
Nominal input frequency | 50Hz or 60Hz | ||
Overload protection (SMPS Load) | Circuit breaker | ||
Output short circuit protection | Circuit breaker | ||
Bypass breaker rating | 80A | 100A | 100A |
Max bypass current | 36A | 45A | 54.5A |
SOLAR CHARGER | |||
Maximum PV charge current | 100A(200A optional) | ||
DC voltage | 48V | ||
Maximim PV array power | 5000W(10000W for 200A optional) | ||
MPPT range @ operating voltage(VDC) | 64~235VDC | ||
Maximum PV array open circuit voltage | 250VDC | ||
Maximum effciency | >98% | ||
Standby power consumption | <2W | ||
MECHANICAL SPECIFICATIONS | |||
Mounting | Wall mount | ||
Dimensions (W*H*D) | 674*402*222mm | ||
Package Dimensions (W*H*D) | / | ||
N.W (kg) | / | ||
G.W (kg) | / | ||
OTHER | |||
Operation temperature range | 0°C to 50°C | ||
Storage temperature | -15°C to 60°C | ||
Audible noise | 60dB MAX | ||
Display | LED+LCD | ||
Loading (20GP/40GP/40HQ) | 140pcs / 280pcs / 320pcs |