VP300 Off Grid Solar Inverter 1-5KW
Low Frequency Inverter | DC 12/24/48V | PV 245V
VP300 series is very economical pure sine wave solar inverter, Inbuilt with 80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. it enables inverter to operate with all kinds of home appliances.
Description
Product Description
■ 3 Steps charging
■ Overload and short-circuit protection
■ Set charging voltage/charging current
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority /battery priority
■ Set utility input wide/narrow voltage range
■ Inverter voltage can be set to 220V/230V/240V
■ Inverter frequency can be set to 50Hz/60Hz
■ Set utility charging on/off switch
■ Inbuilt 80A MPPT Solar Charge Controller
■ Acid or Lithium Select
■ WIFI remote monitoring (optional)
■ With BMS lithium battery communication function (CAN port)
MODEL | VP300-1012 | VP300-3024 | VP300-5048 |
Nominal Battery System Voltage | 12VDC | 24VDC | 48VDC |
INVERTER OUTPUT | |||
Rated Power | 1 KW | 3 KW | 5 KW |
Surge Rating | 3000VA | 9000VA | 15000VA |
Capable Of Starting Electric Motor | 1HP | 2HP | 3HP |
Waveform | Pure sine wave / same as input (bypass mode) | ||
Nominal Output Voltage RMS | 220V / 230V / 240VAC (±10% RMS) | ||
Output Frequency | 50Hz / 60Hz ±0.3Hz | ||
Inverter Efficiency (Peak) | >88% | ||
Line Mode Efficiency | >95% | ||
Power Factor | 1.0 | ||
Typical Transfer Time | 10ms(max) | ||
Overload | 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | ||
AC INPUT | |||
Voltage | 230VAC | ||
Selectable Voltage Range | 155~265VAC(For personal computers) | ||
Frequency Range | 50Hz / 60Hz(Auto sensing) 40~80Hz | ||
BATTERY | |||
Minimum Start Voltage | (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||
Low Battery Alarm | (10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||
Low Battery Cut Off | 10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||
High Voltage Alarm | (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||
High Battery Voltage Recover | (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | ||
Idie Consumption-Search Mode | Load ≤50±20W(120V)/100±20W(220V) | ||
CHARGER | |||
Output Voltage | Depends on battery type | ||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | ||
Maximum Charge Current | 30A | 40A | 35A |
PAYPASS & PROTECTION | |||
Input Voltage Waveform | Sine wave (grid or generator) | ||
Nominal Input Frequency | 50Hz or 60Hz | ||
Overload Protection (SMPS Load) | Circuit breaker | ||
Output Short Circuit Protection | Circuit breaker | ||
AC Input Breaker | 30A | 50A | |
SOLAR CHARGER | |||
Maximum PV Array Power | 1250W | 2500W | 5000W |
Maximum PV Charge Current | 80A±4A | ||
DC Voltage | 12V/ 24V auto work | 48V auto work | |
MPPT Range @ Operating Voltage | 15~95VDC @ 12V/ 30~230VDC @ 24V | 60~230VDC @ 48V | |
Maximum PV Array Open Circuit Voltage | 245VDC | ||
Standby Power Consumption | <2W | ||
MECHANICAL SPECIFICATIONS | |||
Mounting | Wall Mount | ||
Dimensions (W*H*D) | 303*493*200mm | 305*531*202mm | |
Package Dimensions (W*H*D) | 615*400*319mm | 686*400*319mm | |
N.W (kg) | / | / | |
G.W (kg) | / | / | |
OTHER | |||
Operation Temperature Range | 0°C to 40°C | ||
Storage Temperature | -15°C to 60°C | ||
Audible Noise | 60dB MAX | ||
Display | LED+LCD | ||
Standard Warranty | 1 year |