SC180 MPPT Solar Charge Controller 60/80/100A

SC180 MPPT Solar Charge Controller 60/80/100A

PV 245V | DC 12/24/48V

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.

Description

Product Description

■ LCD display , easy to operate on LCD screen
■ Multi stage charging (3-stage charging , parallel charging and equalized charging function)
■ Maximum Solar Input Voltage: 245V
■ BTS – Battery remote temperature sensor terminal
■ Enable to charge Li-thium, Gel , lead-acid battery
■ With RS485 & USB communication port
■ Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit

MODEL SC800-6025 SC800-8025 SC800-10025
Nominal Battery System Voltage 12V / 24V / 48VDC (Auto detection); 36V (Setting)
CONTROLLER INPUT
Battery Voltage 12V / 24V / 36V / 48V
Battery voltage 12V (VBAT) 100V
24V (VBAT) 245V
36V (VBAT) 245V
48V (VBAT) 245V
PV Array MPPT Voltage Range 12V (VBAT) 15-95V
24V (VBAT) 30~230V
36V (VBAT) 45~230V
48V (VBAT) 60~230V
Maximum Input Power 12V (VBAT) 940W 1250W 1560W
24V (VBAT) 1880W 2500W 3120W
36V (VBAT) 2820W 3750W 4680W
48V (VBAT) 3760W 5000W 6250W
BATTERY
Charging Set Points Flooded Battery Absorption Stage 14.2V / 28.4V / 42.6V / 56.8V
Float Stage 13.7V / 27.4V / 41.1V / 54.8V
AGM
(Default)
Absorption Stage 14.4V / 28.8V / 43.2V / 57.6V
Float Stage 13.7V / 27.4V / 41.1V / 54.8V
Over-charging Voltage 15.5V / 30.0V / 45.0V / 60.0V
Over-charging Comeback Voltage 14.5V / 29.5V / 44.5V / 59.0V
Battery Defect Voltage 10.0V / 17.0V / 25.5V / 34.0V
Temperature Compensation Conefficient -5mv / ℃ /cell (25℃ vef)
Peak Conversion Efficiency 98% (MPPT Efficiency 99%)
Maximum Battery Current 60A 80A 100A
Maximum DC load current / / 100A
Max Charging Current 60amps continuous @ 40℃ ambient 80amps continuous @ 40℃ ambient 100amps continuous @ 40℃ ambient
DISPLAY & PROTECTION
Protections Solar high voltage disconnect/ Solar high voltage reconnect/ Battery high voltage disconnect Battery high voltage reconnect/ High temperature disconnect/ High temperature reconnect
MECHANICAL SPECIFICATIONS
Machine Dimension (W*H*D)(mm) 306.6*163.6*94.9 284*165*97
Package Dimension (W*H*D)(mm) / /
N.W(kg) 3 4
G.W(kg) / /
OTHER
Mounting Wall mount
Environmental Rating Indoor
Enclosure IP20
Radiating Mode Fan cooling
Operation Temperature Range -10~55℃
Ambient Humidity 0~90% relative humidity (non-condensing)
Altiude ≤3000m